Glossary entry

French term or phrase:

Perchage

English translation:

earthing and short-circuiting

Added to glossary by Ginnine Robar
Sep 21, 2016 21:13
7 yrs ago
3 viewers *
French term

Perchage

French to English Tech/Engineering Construction / Civil Engineering Electrical railways
The entire sentence is "Activités de perchage"

This is a safety guidelines document for railway workers.

I was given a definition though: le percharge dans le langage caténaires sert a couper l'alimentation éléctrique dans la zone de travail. 2 perches délimitent de part et d'autre la zone de travail, et les salariés peuvent travailler en toute sécurité, car il n'y a pas de courant dans cette zone

I haven't been able to find the English term for this safety procedure.

Discussion

Johannes Gleim Sep 22, 2016:
@ Tony Did you note the language direction? It's not French to French, but French to English. 'sectionnement' is French.
Johannes Gleim Sep 22, 2016:
Suite : Une habilitation électrique ne se donne pas à la légère, aucune entreprise ne le fait… Sauf la SNCF qui a décidé que le perchage et la prise de consignation par des agents non spécialistes était possible !
Pourtant les risques et les accidents existe pour les professionnels comme pour les agents non spécialiste, la preuve :
Années 90, au lieu dit « la Sablière » PK 234 à la sortie faisceau VB-V1, un interrupteur caténaire fond suite à une erreur d’un Surveillant de Tx Voie chargé de Percher.
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...
Johannes Gleim Sep 22, 2016:
LE PERCHAGE CATENAIRE, je me souviendrais toujours d'un retard d'une heure que mon train avait subi à Salbris et qui aurait pu être pire. Je m'explique, un TER assurant un Vierzon-Orléans et marquant un arrêt commercial en gare de Salbris voit une perche caténaire sur la voie contigüe, là rien d'anormal des travaux un peu plus loin sans doute, sauf que déboulant en tromble à sa vitesse max autrement dit 200km/h mon train qui file tout droit vers cette perche. Là plus de doute possible un oubli et plus qu'à actionner l'alerte radio pour arrêter le train croiseur avant l'obstacle.
Voilà un exemple de dérive de la sous-traitance qui a vu l'emergence de petites entreprises se spécialisant du jour au lendemain dans la maintenance ferroviaire et dans cette exemple précis bossant avec du matériel non homologué ou défectueux, car avec une perche conforme jamais le courant n'aurait pu être remis.
http://www.cheminots.net/forum/topic/32746-fonctions-dun-con...
Johannes Gleim Sep 22, 2016:
perchage - perche A “perche” is an “earthing rod” used to connect the overhead contact line to the rail on both sides of the site for maintenance work. This denotes earthing the OCL. A track has 2 rails, which are also connected to each other (considering the track circuit system, single or double track) and adjacent metal constructions. This signifies “short-circuiting”. Short-circuiting shall never be made with live OCL. Connecting both rails short circuits the track circuits and indicates an occupied track in the signal box. This places all relevant signals at stop, switches the entry and outlet points correspondingly and prevents trains to drive into the worksite. In addition the site is monitored and protected by lookout flagmen with horn. This is the whole procedure.

“perchage” in narrower sense means only to hook-in the rod. But the context indicates the wider sense: making the contact line dead. This implies the complete procedure. I cite: « le perchage dans le langage caténaires sert a couper l'alimentation éléctrique dans la zone de travail. »

Proposed translations

+1
13 hrs
Selected

earthing and short-circuiting

perche à décrocher ~ de décalage / shunter’s pole
perche de mise à la terre / earthing rod {pole}
(UIC, Lexique général des termes ferroviaires)

Voici un cliché :

Perchage de la LAC au voisinage de Porte d'Ivry.
https://fr.wikipedia.org/wiki/Ligne_3a_du_tramway_d'Île-de-F...

Record 31 2009-10-09
English
Subject field(s)
• Electrical Engineering
earthing pole
earthing stick

French
Domaine(s)
• Électrotechnique
perche de mise à la terre
http://www.btb.termiumplus.gc.ca/tpv2alpha/alpha-eng.html?la...


Telescopic-Earthing-Bar Type PES
Application:
Fixing of contact wire clamp type SKH for temporary earthing of overhead lines. 1 )
:
Can be combined with contact wire clamp SKH, various earthing cables and rail clamps.
http://www.aflury.com/GetAttachment.axd?attaName=AF_Info_Tel...

Une étude doit être réalisée afin d'examiner la possibilité d'étendre les modifications apportées à Kerrobert aux autres installations du réseau d'Enbridge où des opérations de débrochage et de mise à la terre sont menées, notamment l'utilisation de perches isolantes télescopiques pour vérifier la tension et faire la mise à la terre ainsi que le recours à un essai de claquage avant de procéder à la mise à la terre.
neb-one.gc.ca
Investigate the feasibility of applying the changes made in the Kerrobert area to other locations on the Enbridge system where racking and grounding tasks are performed, including the use of telescoping hot sticks for voltage testing and applying safety grounds, and conducting a flash test prior to installing grounds.
neb-one.gc.ca
http://www.linguee.fr/francais-anglais/traduction/perches de...

http://www.btb.termiumplus.gc.ca/tpv2alpha/alpha-eng.html?la...

UIC CODE 791-1
Maintenance guidelines for overhead contact lines
:
8.1 – Potential sources of danger
:
Dangerous conditions connected with the works carried out may be due to incorrect behaviour by workers regarding:
- The fixing of the earthing and short circuit devices (between OCL and rail, feeder and rail, shunting of rails, shunting of metallic parts to earth, etc.),
:
8.2.2 . Electrical safety distance
:
When during the intervention, the likelihood of entering into zones inside the safety distance becomes substantial and it is not possible to reduce the risk to zero, the work must be stopped or work continued after the circuit breakers has been extended to any other parts concerned, such as switching off an earthing de OCL on the adjacent tracks.
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...

The overhead line is then earthed, either by the earthing rod or an automatic ..
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...

BS EN 50122-1:2011+A2:2016
Railway applications. Fixed installations. Electrical safety, earthing and the return circuit. Protective provisions against electric shock
http://shop.bsigroup.com/ProductDetail?pid=00000000003032797...

Note: I tried to remember the dedicated term for earthing and short-circuiting procedure I was familiar with during my activity with the German railway and railway engineering offices. Even I searched the internet, no other term was found.

"The greatest challenge in this project was finding a solution for safely and feasibly earthing and short-circuiting the traction current supply lines," reports Jürgen Finsinger, PFISTERER Product Manager for Safety Equipment, "because the usual procedure with standard equipment could not be used in this tunnel." In classic earthing and short-circuiting of open-air railway lines, earthing equipment would be connected so that a train would break it away as it passed (page 6, lower left image). Therefore, in this configuration, the train operation would be regulated according to sections of track.
A mounting bracket and torque-controlled mounting head for the earthing rod make the earthing equipment easy to handle. These features work together ideally during installation: First, the return conductor clamp is put on the earthing rod to hoist and suspend the return conductor. To allow the clamps to withstand the enormous dynamic forces if a short circuit occurs, they are screwed down to the line reliably by means of the earthing rod.
Once a specific torque is reached, the mounting head releases the return conductor clamp, which is now attached optimally, and only after this happens can the installer remove the earthing rod from the clamp.
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...

Earthing and short-circuiting equipment
Nomenclature
Portable earthing equipment
Equipment which is brought and connected to parts of electric installations for earthing or earthing and shor-tcircuiting purposes by hand, with insulating component( s). The equipment comprises earthing components, short-circuiting components and one or more insulating components, for instance insulating poles.
Earthing Device
The earthing device is designed to connect a conductor to earth and comprises a line clamp, cable and earth clamp / earth connection.
Short-Circuiting Device
Device for interconnecting conductors for short-circuiting purposes. The short-circuiting device comprises line clamps and cable or short-circuiting bar.
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...

SAFETY EQUIPMENT for Railway Systems
Railways (Catenary Wire)
Earthing Components
Phase clamps 8
Clamps for contact wires 10
Earthing clamps 12
Rail earthing clamps 14
Earthing and short-circuiting cables 16
Ball point connectors 17
Earthing Rods
Telescopic earthing rods 18
Earthing rods with plug-in connections 19
:
All extendable earthing rods are designed for the requirements of earthing and short-circuiting electric contact wires. They are used to guide one-polar devices to catenaries, feeders, and traction power lines.
http://arcus-schiffmann.de/index.php/en/elektroschutz/bahn/r...

Earthing and short-circuiting equipment is offered by different companies:
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...
http://www.rail.com.my/interlocked-h-v-overhead-traction-lin...
Peer comment(s):

neutral Tony M : Earthing / shorting can only take place once the power has been cut off. / Yes, but the 'perchage' specifically refers to the FIRST action (disconnection), as proved by Didier's ref.
3 mins
Oui, le perchage (mise à terre et en court-circuit) n‘est effectué qu‘après la vérification de l’absence de tension au caténaire. C’est que j’ai dit et prouvé. // The source term is French, the corresponding English term is asked.
agree GILLES MEUNIER
4 hrs
Merci !
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thanks! I ultimately used "protective earthing" for my context. Thanks to everyone for their input."
+1
23 mins

sectionnement

I don't know if this term is used in railways, neither od I know exactly what 'perchage' describes: it might be the action of using a long pole to disconnect the isolator; or more genarlly, the principle of isolating a section of catenary, which is certainly akin to the notion of 'sectionnement' in standard electrical terminology.

--------------------------------------------------
Note added at 47 minutes (2016-09-21 22:00:47 GMT)
--------------------------------------------------

They could, of course, also be EARTHING poles, so that once the power has been isolated elsewhere, the section of circuit is earthed at both ends, so you can be SURE the power won't come back on!

--------------------------------------------------
Note added at 13 heures (2016-09-22 11:02:32 GMT)
--------------------------------------------------

OK, so Didier's very helpful refs. do indeed confirm that this is referring to the use of 'disconnect sticks' to operate the circuit-breakers that will thus isolate a section of line from the power supply; the particular feature of this railway usage seems to be that these insulated operating poles are the left in place as a clear indicator that the circuit has indeed been disconnected.

--------------------------------------------------
Note added at 20 heures (2016-09-22 17:43:30 GMT)
--------------------------------------------------

Oops, Johannes has just pointed out my language error!

OK, so the equivalent term in EN would then be 'isolation'

I HAVE come across 'sectioning' in electrical in EN, but I remain always very wary of this; naturally, one may well be talking about 'isolating power from one section of a system' (particularly applicable when that system is in some sense linear).

But I stand by my original comments: as described in Didier's exactly on-context ref., this is about using poles to operate high-level disconnectors; there is no mention either in the source text or in the reference given about the specific use of earthing poles, which is a different part of the same procedure.
Peer comment(s):

neutral Johannes Gleim : The UIC lexique mentions "mechanical sectioning, constructional overlap (contact line)" and "sectioning of station tracks" different contexts. // Earthing is not the 1st action, but switching off the OCL, followed by earthing and short-circuiting.
13 hrs
Danke, Johannes! But that's in ENGLISH; this IS a standard term used in HV work in FR! And now Didier has confirmed it does refer to the same action.
agree Kim Metzger
15 hrs
Thanks, Kim!
Something went wrong...
14 days

cutting (breaking) (turning off) a catenary section

for maintenance purposes

Il existe sur la caténaire des disjoncteurs de chaque côté de la rupture de phase

Section Breaks

Section breaks are gaps in the overhead catenary wires. In this way, each section of catenary can be turned on or off individually.
To allow maintenance to the overhead line without having to turn off the entire system, the line is broken into electrically separated portions known as "sections". Sections often correspond with tension lengths as described above. The transition from section to section is known as a "section break"
Peer comment(s):

neutral Tony M : 'cutting' would be incorrect here in EN, we could only talk about 'cutting power to...'
18 mins
Something went wrong...

Reference comments

13 hrs
Reference:

insulating sticks / poles

Une perche en français est un long bâton isolant destiné à actionner à distance un coupe-circuit haute tension:
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
"insulating stick" selon Electropedia mais j'ai souvent vu "pole" (don't touch it with a 10-foot pole")

Les ouvriers du rail actionnent les coupe-circuits de part et d'autre de la zone de travail et laissent les perches en évidence pour indiquer la coupure, d'où le terme "perchage"

Les outils pour faire la même chose en anglais, mais je ne sais pas s'il existe un terme équivalent
http://www.substation-safety.com/electrical-safety/railway-e...
http://www.substation-safety.com/electrical-safety/operating...
Peer comments on this reference comment:

agree Tony M : We talk about 'disconnect stick', however the '-age' indicates the action, not the object. The 'leaving the poles in position' seems to be the specifically railway bit!
22 mins
That's why this is a reference and not an answer, I know how to translate "perche", not the "-age" part
agree Johannes Gleim : OK for perche.
23 mins